Elindult a Jedlik Ányos Energetikai Program!
Akár 1 Mrd forint támogatás energiatárolásra és energetikai fejlesztésre.
A pályázat benyújtása 2026. január 12-én indul – kérjen ajánlatot még ma, hogy időben le tudja adni pályázatát!
Akár 2,5 millió forint állami támogatás otthoni akkumulátorra
Kérjen ajánlatot még ma, hogy időben le tudja adni pályázatát!
Items | Parameters | Basic index | ||||
|---|---|---|---|---|---|---|
Rated power | 50kW | 60kW | 80kW | |||
Dimensions (wxdxh) | 800mm x 500mm x 1800mm | |||||
Charging outlet | CSS2+CHAdeMO(optional), length; 5m | |||||
HMI | 10.1 inch, color rouch screen | |||||
Installion | Ground mounted | |||||
Communication | ||||||
EVSE | PLC(DIN 70121:2104-12 /ISO15118) | |||||
Back-end protocol | OCCP 1.6/OCPP 2.0 (upgradeable) | |||||
Method of Payment | ||||||
Payment mode | Optional: RFID Card / POS | |||||
Input characterictics | ||||||
Frequency | 50 Hz | |||||
Power factor | >0.98 (50% ~ 100% load) | |||||
Harmonic | iTHD<5% | |||||
Output Characteristic | ||||||
Voltage | DC 200~1000V | |||||
Current | CCS2 30OA max.
CHAdeMO 125A max | |||||
Power | CSS2 120kW max.
CHAdeMO 62.5kW max. | CSS2 150kW max.
CHAdeMO 62.5kW max. | CSS2 160kW max.
CHAdeMO 62.5kW max. | |||
Peak efficiency | >95% | |||||
Charging way | Meantime | |||||
Environmental indicators | ||||||
Operating tempreature | -30 °C ~ +50 °C | |||||
Relative humidity | 5% – 95% without condensation | |||||
Working altitude | <2000M | |||||
Protection grade | IP54 | |||||
Application site | Indoor / Outdoor | |||||
Cooling method | Inteligence air forced cooling | |||||
Noise | <60db | |||||
Markings | ||||||
Certification | CE, CB, UKCA, TR25 | |||||
Weight | ||||||
Net weight | <330kg | |||||
Gross weight | <400kg | |||||
Items | Parameters | Basic index | ||
|---|---|---|---|---|
Rated power | 120kW | 150kW | 160kW | |
Dimensions (wxdxh) | 850mm x 610mm x 2000mm | |||
Charging outlet | CSS2+CHAdeMO(optional), length; 5m | |||
HMI | 10.1 inch, color rouch screen | |||
Installion | Ground mounted | |||
Communication | ||||
EVSE | PLC(DIN 70121:2104-12 /ISO15118) | |||
Back-end protocol | OCCP 1.6/OCPP 2.0 (upgradeable) | |||
Method of Payment | ||||
Payment mode | Optional: RFID Card / POS | |||
Frequency | 50 Hz | |||
Power factor | >0.98 (50% ~ 100% load) | |||
Harmonic | iTHD<5% | |||
Output Characteristic | ||||
Voltage | DC 200~1000V | |||
Current | CCS2 30OA max.
CHAdeMO 125A max | |||
Power | CSS2 120kW max.
CHAdeMO 62.5kW max. | CSS2 150kW max.
CHAdeMO 62.5kW max. | CSS2 160kW max.
CHAdeMO 62.5kW max. | |
Peak efficiency | >95% | |||
Charging way | Meantime | |||
Environmental indicators | ||||
Operating tempreature | -30 °C ~ +50 °C | |||
Relative humidity | 5% – 95% without condensation | |||
Working altitude | <2000M | |||
Protection grade | IP54 | |||
Application site | Indoor / Outdoor | |||
Cooling method | Inteligence air forced cooling | |||
Noise | <60db | |||
Markings | ||||
Certification | CE, CB, UKCA, TR25 | |||
Weight | ||||
Net weight | <330kg | |||
Gross weight | <400kg | |||
Items | Parameters | Basic index | ||
|---|---|---|---|---|
Rated power | 180kW | 240kW | ||
Dimensions (wxdxh) | 850mm x 800mm x 2000mm | |||
Charging outlet | CSS2+CHAdeMO(optional), length; 5m | |||
HMI | 10.1 inch, color rouch screen | |||
Energy master | MID | |||
Installion | Ground mounted | |||
Communication | ||||
EVSE | PLC(DIN 70121:2104-12 /ISO15118) | |||
Back-end protocol | OCCP 1.6/OCPP 2.0 (upgradeable) | |||
Method of Payment | ||||
Payment mode | Optional: RFID Card / POS | |||
Input characterictics | ||||
Input voltage | 400VAC ±10%, three-phase+N+PE | |||
Frequency | 50 Hz | |||
Power factor | >0.98 (50% ~ 100% load) | |||
Harmonic | iTHD<5% | |||
Output Characteristic | ||||
Voltage | DC 200~1000V | |||
Current | CCS2 30OA max.
CHAdeMO 125A max | |||
Power | CSS2 180kW max.
CHAdeMO 62.5kW max. | CSS2 240kW max.
CHAdeMO 62.5kW max. | ||
Peak efficiency | >95% | |||
Charging way | Meantime | |||
Environmental indicators | ||||
Operating tempreature | -30 °C ~ +50 °C | |||
Relative humidity | 5% – 95% without condensation | |||
Working altitude | <2000M | |||
Protection grade | IP54 | |||
Application site | Indoor / Outdoor | |||
Cooling method | Inteligence air forced cooling | |||
Noise | <60db | |||
Markings | ||||
Certification | CE, CB, UKCA, TR25 | |||
Weight | ||||
Net weight | <440kg | |||
Gross weight | <530kg | |||
Items | Parameters | Basic index | ||
|---|---|---|---|---|
Rated power | 320kW | 400kW | ||
Dimensions (wxdxh) | 850mm x 1100mm x 2100mm | |||
Charging outlet | CSS2+CHAdeMO(optional), length; 5m | |||
HMI | 10.1 inch, color rouch screen | |||
Energy master | MID | |||
Installion | Ground mounted | |||
Communication | ||||
EVSE | PLC(DIN 70121:2104-12 /ISO15118) | |||
Back-end protocol | OCCP 1.6/OCPP 2.0 (upgradeable) | |||
Method of Payment | ||||
Payment mode | Optional: RFID Card / POS | |||
Input characterictics | ||||
Input voltage | 400VAC ±10%, three-phase+N+PE | |||
Frequency | 50 Hz | |||
Power factor | >0.98 (50% ~ 100% load) | |||
Harmonic | iTHD<5% | |||
Output Characteristic | ||||
Voltage | DC 200~1000V | |||
Current | CCS2 30OA max.
CHAdeMO 125A max | |||
Power | CSS2 320kW max.
CHAdeMO 62.5kW max. | CSS2 400kW max.
CHAdeMO 62.5kW max. | ||
Peak efficiency | >95% | |||
Charging way | Meantime | |||
Environmental indicators | ||||
Operating tempreature | -30 °C ~ +50 °C | |||
Relative humidity | 5% – 95% without condensation | |||
Working altitude | <2000M | |||
Protection grade | IP54 | |||
Application site | Indoor / Outdoor | |||
Cooling method | Inteligence air forced cooling | |||
Noise | <65db | |||
Markings | ||||
Certification | CE, CB, UKCA, TR25 | |||
Weight | ||||
Net weight | <580kg | |||
Gross weight | <710kg | |||